How to read a wire crimp pull test result
A pull test on a ring terminal can end three ways: the conductor pulls out of the crimp, the wire breaks, or the wire slips in the grip. All three can leave a peak on the screen. To interpret that peak, record what happened to the specimen. Start with the terminal and wire For a
How to read a wire crimp pull test result Read More »